home *** CD-ROM | disk | FTP | other *** search
/ Columbia Kermit / kermit.zip / newsgroups / misc.19951130-19960209 / 000332_news@columbia.edu _Tue Jan 23 12:21:47 1996.msg < prev    next >
Internet Message Format  |  2020-01-01  |  2KB

  1. Return-Path: news@columbia.edu
  2. Received: from apakabar.cc.columbia.edu (apakabar.cc.columbia.edu [128.59.35.159]) by watsun.cc.columbia.edu (8.7.3/8.7.3) with ESMTP id MAA24323 for <kermit.misc@watsun>; Tue, 23 Jan 1996 12:21:46 -0500 (EST)
  3. Received: (from news@localhost) by apakabar.cc.columbia.edu (8.7.3/8.7.3) id MAA13712 for kermit.misc@watsun; Tue, 23 Jan 1996 12:21:43 -0500 (EST)
  4. Path: news.columbia.edu!watsun.cc.columbia.edu!fdc
  5. From: fdc@watsun.cc.columbia.edu (Frank da Cruz)
  6. Newsgroups: comp.protocols.kermit.misc
  7. Subject: Re: PC Connection Problems
  8. Date: 23 Jan 1996 17:21:22 GMT
  9. Organization: Columbia University
  10. Lines: 31
  11. Message-ID: <4e35ei$dca@apakabar.cc.columbia.edu>
  12. References: <4e10qq$s3u$1@mhade.production.compuserve.com>
  13. NNTP-Posting-Host: watsun.cc.columbia.edu
  14.  
  15. In article <4e10qq$s3u$1@mhade.production.compuserve.com>,
  16. Rich Godlewsky 76412.156@compuserve.com  <76412.156@CompuServe.COM> wrote:
  17. : We are using kermit to transfer files between two PC's via modem. 
  18. : However, sometimes we are unable to connect the PC's at the same 
  19. : baud rate (i.e., 9600).  In the mscustom.ini we have "set baud 
  20. : 9600" and we also have "AT %B9600" to set the baud rate between 
  21. : the modem and the PC.  However, often when trying to connect we 
  22. : will see on the dailing PC CONNECT 9600 but on the answering PC 
  23. : we see CONNECT 7200.  Any ideas of what else needs to be set.
  24. This usually means that conditions on the connection between the
  25. two modems were not good enough to sustain 9600 bps, and so they
  26. negotiated to a fallback speed.
  27.  
  28. You need to configure your modems to keep their interface speed
  29. fixed at 9600 (or whatever), regardless of the connection speed.
  30. And obviously, you also need effective and instantaneous flow
  31. control between each modem and its computer, ideally RTS/CTS.
  32. So both modems and both copies of Kermit should be configured for
  33. RTS/CTS flow control.
  34.  
  35. : We are also trying to use the "SET PORT 2" command in 
  36. : mscustom.ini but receive a warning that have "unknown hardware 
  37. : for port2"  Any ideas of what is wrong (note, these are standard 
  38. : 486 stand alone PCs).
  39. The current version of MS-DOS Kermit is 3.14.  It comes with a file
  40. called KERMIT.BWR that should contain the answer to your question.
  41. If you are not using version 3.14, please upgrade.